{"product_id":"abb-ot63f6-switch-disconnector","title":"ABB OT63F6 Switch-Disconnector","description":"\u003ch4\u003eABB OT63F6 Switch-Disconnector  Specifications:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Switch-Disconnector (Non-Fusible Disconnect Switch)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: ABB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003e: OT63F6 (Product ID: 1SCA105379R1001)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice Application\u003c\/strong\u003e: Isolation, manual switching, and disconnection in low-voltage circuits (e.g., power distribution, motor control centers)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles Description\u003c\/strong\u003e: 6P (6 poles)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Current AC-21A (Ie)\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e63 A at 380–415 V\u003c\/li\u003e\n\u003cli\u003e63 A at 500 V\u003c\/li\u003e\n\u003cli\u003e63 A at 690 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Current AC-22A (Ie)\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e63 A at 380–415 V\u003c\/li\u003e\n\u003cli\u003e63 A at 500 V\u003c\/li\u003e\n\u003cli\u003e63 A at 690 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Current AC-23A (Ie)\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e63 A at 380–415 V\u003c\/li\u003e\n\u003cli\u003e45 A at 500 V\u003c\/li\u003e\n\u003cli\u003e20 A at 690 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Power AC-23A (Pe)\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e11 kW at 220–240 V\u003c\/li\u003e\n\u003cli\u003e22 kW at 400–415 V\u003c\/li\u003e\n\u003cli\u003e22 kW at 500 V\u003c\/li\u003e\n\u003cli\u003e15 kW at 690 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConventional Free-air Thermal Current (Ith)\u003c\/strong\u003e: 63 A at 40 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConventional Thermal Current (Ithe)\u003c\/strong\u003e: 63 A (fully enclosed)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Voltage\u003c\/strong\u003e: 750 V AC (main circuit)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Operating Voltage UL\/CSA\u003c\/strong\u003e: 600 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e: 750 V (IEC\/EN 60664-1)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e: 8 kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Conditional Short-Circuit Current (Inc)\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e50 kA with 100 A fuse at ≤415 V\u003c\/li\u003e\n\u003cli\u003e100 kA with 100 A fuse at 500 V\u003c\/li\u003e\n\u003cli\u003e50 kA with 80 A fuse at 690 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Short-Circuit Making Capacity (Icm)\u003c\/strong\u003e: 1.4 kA at 690 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Short-time Withstand Current (Icw)\u003c\/strong\u003e: 1.5 kA for 1 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Loss\u003c\/strong\u003e: 2.8 W per pole at rated operating conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Mode\u003c\/strong\u003e: Front operated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandle Type\u003c\/strong\u003e: Knob handle (handle and shaft not included)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Type\u003c\/strong\u003e: Base mounting, DIN-rail mountable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePosition of Line Terminals\u003c\/strong\u003e: Top In – Bottom Out or Bottom In – Top Out\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type\u003c\/strong\u003e: Screw terminals with protected clamp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Cross-Section\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eFlexible with Ferrule: 1 x 1.5–4 mm²\u003c\/li\u003e\n\u003cli\u003eSolid: 1 x 1.5–6 mm²\u003c\/li\u003e\n\u003cli\u003eFlexible: 1 x 1.5–35 mm²\u003c\/li\u003e\n\u003cli\u003eStranded: 1 x 1.5–35 mm²\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Stripping Length\u003c\/strong\u003e: 10–12 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTightening Torque\u003c\/strong\u003e: 2 N·m (IEC 60947-1); 18 in·lb (UL\/CSA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended Screw Driver\u003c\/strong\u003e: Pozidriv 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e: Front IP20 (IEC 60529)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution Degree\u003c\/strong\u003e: 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Durability\u003c\/strong\u003e: 20,000 cycles\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmpere Rating UL\/CSA\u003c\/strong\u003e: 60 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHorsepower Rating UL\/CSA\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eSingle Phase:\n\u003cul\u003e\n\u003cli\u003e2 Hp at 110–120 V AC\u003c\/li\u003e\n\u003cli\u003e7.5 Hp at 240 V AC\u003c\/li\u003e\n\u003cli\u003e15 Hp at 440–480 V AC\u003c\/li\u003e\n\u003cli\u003e15 Hp at 550–600 V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThree Phase:\n\u003cul\u003e\n\u003cli\u003e15 Hp at 220–240 V AC\u003c\/li\u003e\n\u003cli\u003e30 Hp at 440–480 V AC\u003c\/li\u003e\n\u003cli\u003e30 Hp at 550–600 V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eIEC 60947-3\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No. 14\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Certifications\u003c\/strong\u003e: CE, cULus, RoHS (EU Directive 2011\/65\/EU and Amendment 2015\/863), REACH, TSCA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecial Features\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eCompact design for space-saving installation\u003c\/li\u003e\n\u003cli\u003eVisible contacts for safety (for 100 A and above, applicable to series)\u003c\/li\u003e\n\u003cli\u003eModular design for faster installation and accessory compatibility\u003c\/li\u003e\n\u003cli\u003eKnife contact solution for low power loss and heat\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eWidth: 105 mm\u003c\/li\u003e\n\u003cli\u003eHeight: 91.5 mm\u003c\/li\u003e\n\u003cli\u003eDepth\/Length: 84.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.6 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHS Code\u003c\/strong\u003e: 8536.50.80 \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Finland \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Used Industrial Parts","offers":[{"title":"Default Title","offer_id":53052896313686,"sku":"AA-01-07-03-6152427492471","price":75.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0878\/9989\/8198\/files\/ABB-OT63F6-Switch-Disconnector-Switch-Disconnector-Used-Industrial-Parts_bccd16cd-2c71-451a-b824-f98ebf442308.jpg?v=1780231263","url":"https:\/\/www.laskoning.com\/products\/abb-ot63f6-switch-disconnector","provider":"Laskoning","version":"1.0","type":"link"}